Description: CA10S Capnograph IntroductionThe device adopts sidestream method to measure the parameter related to ETCO2 and AWRR. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow and indirectly reflect the alveolar ventilation. Meanwhile, it can also detect the blood oxygen saturation and pulse.The application population is adult patient. It is applicable for use in emergency department, ICU, operating room, respiratory department and other occasions. It is connected to the nose end of the patient through the sampling tube (applied part) .Features1)End-tidal CO2 measurement function;2)Respiration rate measurement function;3)SpO2 measurement function;4)Pulse rate measurement function;5)Optional three units;6)With audible and visual alarm and silencing functions, the alarm limit can be set;7)Over-limit alarm function for EtCO2, Respiration rate, SpO2 and Pulse rate;8)Low battery alarm function;9)With the prompt function of “Checking Filterline”;10)User can calibrate zero by themselves.11)With atmospheric pressure and temperature compensation functions12)Rechargeable lithium battery, up to 8-hour user time;PerformanceEnd-tidal CO2 measurement:1)Measurement range: 0 mmHg ~ 150mmHg2)Resolution: 1mmHg3)Accuracy:0 mmHg ~ 40 mmHg:±2 mmHg;41 mmHg ~ 70 mmHg:±5% of readings;71 mmHg ~ 100 mmHg:±8% of readings;101 mmHg ~ 150 mmHg:±10% of readings.Respiration rate measurement:1)Measurement range: 2rpm~120rbpm;2)Resolution: 1rpm;3)Accuracy: ±1rpm.SpO2 measurement:1)Measurement range: 30 % ~100 %;2)Resolution: 1 %;3)Accuracy: 70 % ~ 100 %:2 %; 30 % ~ 69 %:undefinition.Pulse rate measurement:1)Measurement range: 25 bpm ~ 250 bpm;2)Resolution: 1bpm;3)Accuracy: ±2 bpm or ±2%,whichever is greater.Safety characteristic:1)Device type: internally powered equipment;2)Degree of protection against electric shock: type BF applied part;3)Degree of protection against ingress of liquid: IPX1.Other parameters:1)Preheat time: 2min;2)Response time: < 3s;3)Alarm sound pressure level: 50 dB;4)Battery life time: 8hours;5)Gas sampling rate: 60 ml/min ~ 100 ml/min.AccessoriesUser ManualBlood oxygen probeSampling tube(Nasal tube with filter cotton)USB cablePhysical CharacteristicDimension: 159*72*31 mmWeight: 270 gWorking environmentTemperature: 5℃~40℃Relative humidity: 30%~ 75%, no condensationAtmospheric pressure: 700hPa~1060hPaPower supply: DC 3.7V (rechargeable lithium batteries)Input power: ≤1.5VA
Price: 299 USD
Location: beijing
End Time: 2024-07-25T07:16:19.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Oximeter Type: Array
MPN: Does Not Apply
Caratteristiche: Array
Monitor Parameters: CO2 - EtCO2, Array
Intended Use/Discipline: Array
Brand: CONTEC
Form Factor: Handheld
Marke: CONTEC
Technology: Digital
Features: Array
Country/Region of Manufacture: China
Características: Array
Caractéristique: Array